国产欧美精品一区二区,中文字幕专区在线亚洲,国产精品美女网站在线观看,艾秋果冻传媒2021精品,在线免费一区二区,久久久久久青草大香综合精品,日韩美aaa特级毛片,欧美成人精品午夜免费影视

基于聯(lián)合壓縮感知重構的網(wǎng)絡(luò )通信故障檢測系統設計
DOI:
CSTR:
作者:
作者單位:

云南省互聯(lián)網(wǎng)應急中心,北京郵電大學(xué)

作者簡(jiǎn)介:

通訊作者:

中圖分類(lèi)號:

基金項目:


Design of Network Communication Fault Detection System Based on Joint Compressed Sensing Reconfiguration
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪(fǎng)問(wèn)統計
  • |
  • 參考文獻
  • |
  • 相似文獻
  • |
  • 引證文獻
  • |
  • 資源附件
  • |
  • 文章評論
    摘要:

    針對當前故障檢測系統檢測網(wǎng)絡(luò )通信故障信號時(shí)存在不精準的問(wèn)題,設計了基于聯(lián)合壓縮感知重構的網(wǎng)絡(luò )通信故障檢測系統。結合聯(lián)合壓縮感知理論,設計系統總體結構。選用光時(shí)域反射儀F7高端電信級光纜故障光纖測試儀OTDR作為系統硬件,依據工作原理,判斷通信網(wǎng)絡(luò )傳輸特性,設置菜單按鈕,縮放、等比、還原檢測出的波形。采用AD8066型號低噪聲放大器,設計電流電壓轉換電路,在反饋電阻兩端并聯(lián)一個(gè)電容以抑制噪聲,并利用單色驅動(dòng)器24-40W激光驅動(dòng)器為激光電源提供電流,使脈沖信號轉換為電信號。在J2SE平臺下,設計中心服務(wù)功能,通過(guò)激光驅動(dòng)發(fā)射正脈沖,使格雷互補碼偏置到峰值的一半左右,實(shí)現格雷互補碼在OTDR中應用,依據系統檢測流程,完成網(wǎng)絡(luò )通信故障檢測。系統性能測試結果表明,基于聯(lián)合壓縮感知重構檢測系統對網(wǎng)絡(luò )通信故障信號檢測結果較為精準,誤差最大為0.3dB,為網(wǎng)絡(luò )運行維護奠定基礎。

    Abstract:

    Absrtact: Aiming at the inaccuracy of the current fault detection system when detecting the network communication fault signal, a network communication fault detection system based on joint compressed sensing reconstruction is designed. Combined with the theory of joint compressed sensing, the overall structure of the system is designed. The optical time domain reflectometer F7 high-end carrier-grade optical cable fault optical fiber tester OTDR is selected as the system hardware. According to the working principle, the transmission characteristics of the communication network are judged, the menu button is set, the zoom, the equal ratio, and the detected waveform are restored. The AD8066 low noise amplifier is used to design a current-to-voltage conversion circuit. A capacitor is connected in parallel across the feedback resistor to suppress noise, and a 24-40W laser driver is used to supply current to the laser power source to convert the pulse signal into an electrical signal. Under the J2SE platform, the design center service function transmits a positive pulse through the laser drive, and the Gray complementary code is biased to about half of the peak value. The Gray complementary code is applied in the OTDR, and the network communication fault detection is completed according to the system detection process. The system performance test results show that the detection result of the network communication fault signal based on the joint compressed sensing reconstruction detection system is more accurate, and the error is 0.3dB, which lays a foundation for network operation and maintenance.

    參考文獻
    相似文獻
    引證文獻
引用本文

李沛林.基于聯(lián)合壓縮感知重構的網(wǎng)絡(luò )通信故障檢測系統設計計算機測量與控制[J].,2020,28(7):50-54.

復制
分享
文章指標
  • 點(diǎn)擊次數:
  • 下載次數:
  • HTML閱讀次數:
  • 引用次數:
歷史
  • 收稿日期:2019-10-25
  • 最后修改日期:2019-10-25
  • 錄用日期:2019-11-19
  • 在線(xiàn)發(fā)布日期: 2020-07-14
  • 出版日期:
文章二維碼
通道| 铜鼓县| 通江县| 修文县| 沂南县| 安溪县| 阳朔县| 六安市| 扶绥县| 长宁县| 门头沟区| 剑川县| 宁强县| 中超| 资阳市| 芦溪县| 峡江县| 迁安市| 上高县| 九寨沟县| 尤溪县| 深圳市| 班玛县| 莎车县| 共和县| 柘城县| 灵寿县| 玛多县| 淮阳县| 历史| 博客| 肇东市| 横峰县| 馆陶县| 长泰县| 大田县| 滨州市| 仙桃市| 威宁| 正蓝旗| 丹江口市|