水下通信中的異常聲壓監控網(wǎng)絡(luò )系統設計
DOI:
CSTR:
作者:
作者單位:

(河南濮陽(yáng)職業(yè)技術(shù)學(xué)院 數學(xué)與信息工程系,河南 濮陽(yáng) 457000)

作者簡(jiǎn)介:

段新華(1980-),女,河南省濮陽(yáng)市人,碩士研究生,講師,主要從事高性能計算、計算機網(wǎng)絡(luò )方向的研究。 [FQ)]

通訊作者:

中圖分類(lèi)號:

TP391

基金項目:


Design of Abnormal Sound Pressure Monitoring Network in Underwater Rommunication System[HS)]
Author:
Affiliation:

(Department of Mathematics and Information Engineering, Puyang Vocational and Technical College, Puyang 457000, China)

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪(fǎng)問(wèn)統計
  • |
  • 參考文獻
  • |
  • 相似文獻
  • |
  • 引證文獻
  • |
  • 資源附件
  • |
  • 文章評論
    摘要:

    傳統水下通信聲壓異常監控網(wǎng)絡(luò )存在無(wú)法自主完成節點(diǎn)的投放和回收,存儲監控盲區并且無(wú)法進(jìn)行動(dòng)態(tài)組網(wǎng),不能對異常聲壓進(jìn)行準確的監控等較大的缺陷;為此,設計并實(shí)現了一種新的水下異常聲壓監控系統,系統中的通信協(xié)議基于節點(diǎn)間的深度信息完成數據的轉發(fā),給出了系統中監控器、CC2430 處理器、終端節點(diǎn)以及協(xié)調器節點(diǎn)的硬件設計原理并給出了系統采集數據的軟件流程;系統中實(shí)現了對鏈路層的AODV 路由協(xié)議進(jìn)行改進(jìn),增強系統對異常聲壓的監控性能;測試結果說(shuō)明,該系統獲取的聲壓監測星座圖明顯優(yōu)于傳統系統,在不同的干擾類(lèi)型下,發(fā)射信號使用PSK調制,載波中心頻率是10 kHz,采樣率是50 kHz,碼率是2 000 bit/s;實(shí)驗結果表明:該種系統具有較低異常聲壓信號監控誤差率,可對異常聲壓信道的傳輸特性進(jìn)行較好的校正和補償,具有較強穩定性。

    Abstract:

    Traditional underwater communication abnormal sound pressure monitoring network is unable to independently completed node resources and recycling, store the monitoring blind area and the ability for dynamic network, cannot be accurately for abnormal sound pressure monitoring such as larger defects. Therefore, designs and realizes a new kind of underwater abnormal sound pressure monitoring system, communication protocol based on the depth of information between nodes in the system, the complete data forwarding, gives the system monitor, CC2430 processor, terminal node, and the coordinator node hardware design principle, system data software flow is given. Link layer system realized with improved AODV routing protocol, and enhance the system monitoring performance of abnormal pressure. Test results indicate that the acoustic pressure monitoring constellation diagram of the system is obviously better than the traditional system, under the interference of different types, the emission signal using PSK modulation, carrier center frequency is 10 kHz, sampling rate is 50 kHz, bit rate is 2000 bit/s. Experimental results show that this system has a low error rate, abnormal sound pressure signal monitoring for abnormal sound pressure channel transmission characteristics can be better calibration and compensation, has strong stability.

    參考文獻
    相似文獻
    引證文獻
引用本文

段新華.水下通信中的異常聲壓監控網(wǎng)絡(luò )系統設計計算機測量與控制[J].,2014,22(6):1812-1814.

復制
分享
文章指標
  • 點(diǎn)擊次數:
  • 下載次數:
  • HTML閱讀次數:
  • 引用次數:
歷史
  • 收稿日期:2013-08-21
  • 最后修改日期:2013-10-20
  • 錄用日期:
  • 在線(xiàn)發(fā)布日期: 2014-11-12
  • 出版日期:
文章二維碼