基于信號觸發(fā)的電氣線(xiàn)路漏電故障檢測系統
DOI:
CSTR:
作者:
作者單位:

(常州工學(xué)院 計算機信息工程學(xué)院,江蘇 常州 213002)

作者簡(jiǎn)介:

嚴偉中(1977-),男,江蘇常州人,碩士,講師,主要從事計算機軟件工程、移動(dòng)互聯(lián)網(wǎng)應用開(kāi)發(fā)方向的研究。 [FQ)]

通訊作者:

中圖分類(lèi)號:

TP311

基金項目:


Electric Line Fault Leakage Detection System Based on Signal Trigger
Author:
Affiliation:

(Department of Computer and Information Engineering , Changzhou Institute of Technology , Changzhou 213002, China)

Fund Project:

  • 摘要
  • |
  • 圖/表
  • |
  • 訪(fǎng)問(wèn)統計
  • |
  • 參考文獻
  • |
  • 相似文獻
  • |
  • 引證文獻
  • |
  • 資源附件
  • |
  • 文章評論
    摘要:

    低壓電氣線(xiàn)路漏電故障發(fā)掘電路是當電氣網(wǎng)絡(luò )中發(fā)生漏電故障時(shí),通過(guò)對漏電觸發(fā)信號進(jìn)行檢測,從而對故障位置進(jìn)行定位,并切斷電氣線(xiàn)路電源的裝置,確保了供電網(wǎng)絡(luò )的安全性以及可靠性;在對目前低壓電氣線(xiàn)路漏電保護系統研究的基礎上,提出了以STC15F2K60S2單片機為控制核心, 選定的測試模擬觸發(fā)信號漏電流,不小于電氣線(xiàn)路和設備的正常泄漏電流的最大值的2倍;漏電故障測試信號的靈敏度,優(yōu)先考慮30 mA,當額定漏電動(dòng)作電流等于或小于30 mA時(shí)要求保護動(dòng)作時(shí)間小于0.1 s,當額定漏電動(dòng)作電流大于30 mA時(shí)要求小于0.2 s;該裝置是傳統漏電保護裝置的補充, 根據間接漏電檢測與直接漏電檢測結果與實(shí)際的漏電位置距離對比,誤差在10%以?xún)?滿(mǎn)足實(shí)際需要,改善了低壓電氣線(xiàn)路漏電保護系統的保護性能。

    Abstract:

    Low voltage electrical circuit leakage fault excavation is when happen leakage faults in the electrical network, the trigger signal through to carry on the inspection, thereby fixing the fault location, and to cut off the power supply device, electric circuitry to ensure the safety and reliability of power supply network. In the research on the low voltage electrical leakage protection system on the basis of the proposed STC15F2K60S2 single chip microcomputer as control core, the selected test analog trigger signal leakage current, no less than the normal leakage current of electrical wiring and equipment a maximum of 2 times. Leakage fault test signal, the sensitivity of the preferred 30 ma, when the leakage current action rating equal to or less than 30 ma demanding action time is less than 0.1 s, when the leakage current action is more than 30 ma rating requirements is less than 0.2 s. The device is a supplement to the traditional electric leakage protection devices, according to the indirect leakage detection and leakage test results directly compared with the actual leakage location distance, the error is within 10%, meet the actual needs, to improve the protection performance of low voltage electrical leakage protection system.

    參考文獻
    相似文獻
    引證文獻
引用本文

嚴偉中.基于信號觸發(fā)的電氣線(xiàn)路漏電故障檢測系統計算機測量與控制[J].,2014,22(5):1348-1350,1362.

復制
分享
文章指標
  • 點(diǎn)擊次數:
  • 下載次數:
  • HTML閱讀次數:
  • 引用次數:
歷史
  • 收稿日期:2014-01-19
  • 最后修改日期:2014-03-10
  • 錄用日期:
  • 在線(xiàn)發(fā)布日期: 2014-12-16
  • 出版日期:
文章二維碼
通化市| 宣武区| 镇康县| 阜南县| 岗巴县| 横峰县| 新竹县| 沈丘县| 民和| 织金县| 隆昌县| 托克托县| 朔州市| 故城县| 南开区| 永平县| 大渡口区| 弥渡县| 湖南省| 逊克县| 新营市| 岳西县| 贡嘎县| 徐汇区| 西藏| 延边| 建阳市| 浠水县| 日土县| 南靖县| 迁安市| 汽车| 常德市| 柘荣县| 栖霞市| 堆龙德庆县| 息烽县| 金溪县| 富源县| 奉贤区| 靖远县|